COMPRESSION CO N N E C T IO N S C-180 | www.hubbell.com/burndy Electro Tin Plated TYPE YCHC (Continued) Note: To properly use tap 2 and/or tap 3 conductors in YCHC connector a conductor from the tap 1 cable range must be included in the tap 1 groove. ‡ To obtain covers made of polyethylene remove suffix-FR (example: CFO). CFO is not flame retardant. * Use PUADP1 adaptor with U dies in 46 Series. See tooling section of Master Catalog for complete tool and die listings. For applications requiring flame retardant cover, use either a CCFBG- FR (Clear) or CFBG-FR (Black) cover and YH2C2C connector by ordering YH8C8CWCC (Clear) or YH8C8CWC (Black). Note: All dimensions shown are for reference only. Catalog Number Flame Retardant Cover Conductor Sizes Color Code Die Index Clear Cat. No. Black Cat. No. ‡ Main (Run) Tap 1 Tap 2 Tap 3 YCHC44TC44 CCFRFR CFRFR 1000-750 kcmil Class B,C 646-535 kcmil DLO 750-500 kcmil Class I 1000-750 kcmil Class B,C 646-535 kcmil DLO 750-500 kcmil Class I — — White 1102 YCHC39TC39 CCFRFR CFRFR 750-500 kcmil Class B,C 535-373 kcmil DLO 550-500 kcmil Class I 750-500 kcmil Class B,C 535-373 kcmil DLO 550-500 kcmil Class I — — Blue 1103 YCHC39TC31 CCFRFR CFRFR 750-500 kcmil Class B,C 535-373 kcmil DLO 550-500 kcmil Class I 350 kcmil-2 AWG Class B,C 4/0-2 AWG Class I, DLO 2-6 AWG Class B,C,Solid 2-8 AWG Class I, DLO 8-14 AWG Class B,C 8-14 AWG Class I, DLO Blue 1103 YCHC39TC2 CCFRFR CFRFR 750-500 kcmil Class B,C 535-373 kcmil DLO 550-500 kcmil Class I 2-6 AWG Class B,C,Solid 2-8 Class I, DLO 8-14 AWG Class B,C 8-14 AWG Class I, DLO — Blue 1103 YCHC34TC34 CCFNFR CFNFR 500 kcmil-4/0 AWG Class B,C 373 kcmil-4/0 AWG Class I, DLO 500 kcmil-4/0 AWG Class B,C 373 kcmil-4/0 AWG Class I, DLO — — Brown 1104 YCHC34TC29 CCFNFR CFNFR 500 kcmil-4/0 AWG Class B,C 373 kcmil-4/0 AWG Class I, DLO 250 kcmil-2 AWG Class B,C 4/0-2 AWG Class I, DLO 2-6 AWG Class B,C,Solid 2-8 AWG Class I, DLO — Brown 1104 YCHC34TC2 CCFNFR CFNFR 500 kcmil-4/0 AWG Class B,C 373 kcmil-4/0 AWG Class I, DLO 2-6 AWG Class B,C,Solid 2-8 Class I, DLO 8-14 AWG Class B,C 8-14 AWG Class I, DLO — Brown 1104 YCHC29TC29 CCFDXFR CFDFR 250 kcmil-2 AWG Class B,C 4/0-2 AWG Class I, DLO 250 kcmil-2 AWG Class B,C 4/0-2 AWG Class I, DLO — — Orange 997 YCHC29TC2 CCFDFR CFDFR 250 kcmil-2 AWG Class B,C 4/0-2 AWG Class I, DLO 2-6 AWG Class B,C,Solid 2-8 Class I, DLO 8-14 AWG Class B,C 8-14 AWG Class I, DLO — Red 251 YCHC2TC2 CCFOFR CFOFR 2-6 AWG Class B,C,Solid 2-8 Class I, DLO 2-6 AWG Class B,C,Solid 2-8 Class I, DLO 8-14 AWG Class B,C 8-14 AWG Class I, DLO — Brown C YCHC8TC8 8-12 AWG Class B,C 8-12 AWG Class I, DLO 8-12 AWG Class B,C 8-12 AWG Class I, DLO — — Red 240 Catalog Number Flame Retardant Cover Tooling ( No. of Crimps) H W L Strip Length (IN) Clear Cat. No. Black Cat. No. ‡ 750, 35 Series 46* Series † YCHC44TC44 CCFRFR CFRFR — — P1102 1 3.59 1.73 1.16 1-1/4" YCHC39TC39 CCFRFR CFRFR — — P1103 1 3.12 1.53 1.06 1-1/8" YCHC39TC31 CCFRFR CFRFR — — P1103 1 2.96 1.53 1.31 1-3/8" YCHC39TC2 CCFRFR CFRFR — — P1103 1 2.66 1.53 1.31 1-3/8" YCHC34TC34 CCFNFR CFNFR U1104 2 U1104 1 2.97 1.38 1.00 1-1/4" YCHC34TC29 CCFNFR CFNFR U1104 2 U1104 1 2.45 1.26 0.88 1" YCHC34TC2 CCFNFR CFNFR U1104 2 U1104 1 2.45 1.26 0.94 1" YCHC29TC29 CCFDXFR CFDFR U997 1 U997 1 2.12 .98 0.94 1" YCHC29TC2 CCFDFR CFDFR U251 1 U251 1 1.78 .97 0.81 1" YCHC2TC2 CCFOFR CFOFR UC 1 UC 1 1.22 .60 0.81 1" YCHC8TC8 U240 1 U240 1 0.53 .35 0.56 5/8" Copper C-Tap