S MA LL TER M INA L S B-60 | www.hubbell.com/burndy TYPE YSCM HYLINK™ Color-Coded Uninsulated Compression Parallel Splice Catalog Number Conductor Range Cable‡ Dimensions Inches [mm] Color Code Die Index Recommended Installation Tooling Wire Strip† Length Circular Mils L ±.03 O.D. ±.01 500, 600 Series 35, 750 Series Min. Max. YSCM17 13,060 16,910 0.5 [13] 0.27 [7] Red 49 X8CRT, W8CRT U8CRT 11/16 YSCM27 16,910 26,890 0.5 [13] 0.31 [8] Blue 7 X5CRT, W5CRT U5CRT 11/16 YSCM42 29,970 41,520 0.5 [13] 0.38 [10] Gray 8 X4CRT, W4CRT U4CRT 11/16 YSCM66 42,750 66,040 0.62 [16] 0.47 [12] Brown 10 X2CRT, W2CRT U2CRT 3/4 YSCM80 67,980 80,020 0.62 [16] 0.52 [13] Green 11 X1CRT1, W1CRT1 U1CRT1 3/4 YSCM104 82,870 103,630 0.69 [18] 0.57 [14] Pink 12 X25RT, W25RT U25RT 15/16 YSCM133 104,960 133,220 0.81 [21] 0.64 [16] Black 13 X26RT, W26RT U26RT 1-1/16 YSCM167 134,340 166,560 0.81 [21] 0.7 [18] Orange 14 X27RT, W27RT U27RT 1-1/16 YSCM212 167,380 211,820 0.88 [22] 0.78 [20] Purple 15 X28RT, W28RT U28RT 1-1/16 YSCM231 230,800 230,800 1.05 [27] 0.8 [21] Yellow 16 X29RT, W29RT, * U29RT 1-1/16 Circular Mil Table per ASTM B8 Size ASTM Strandings Circular Mils AWG Class Cable Diameter (in) 1,022 20 B 0.036 1,624 18 B 0.045 2,583 16 B 0.057 4,107 14 B 0.072 6,530 12 B 0.091 10,380 10 B 0.116 13,090 9 B 0.130 16,510 8 B 0.146 20,820 7 B 0.164 26,250 6 B 0.184 33,100 5 B 0.206 41,740 4 AA 0.254 41,740 4 B & A 0.232 52,630 3 AA 0.285 52,630 3 B & A 0.260 Notes: Material: Copper per ASTM B75. Finish: Tin plated. For nickel plating, add suffix “NK” to the Catalog Number. Dimensions in brackets [ ] are in millimeters rounded off to the nearest millimeter, unless otherwise noted, and are for reference only. †Recommended strip length. Strip length dependent on size, no. of wires and insulation thickness. ‡Refer to Circular Mil Table per ASTM B8 for total Class B Circular Mil calculations. *YSCM231 can also be installed with MY29-3 and retain Listings. Circular Mil Table per ASTM B8 Size ASTM Strandings Circular Mils AWG Class Cable Diameter (in) 66,370 2 AA 0.320 66,370 2 B & A 0.292 83,690 1 AA 0.360 83,690 1 A 0.328 83,690 1 B 0.332 105,500 1/0 A & A 0.368 105,500 1/0 - 0.390 105,500 1/0 B 0.373 133,100 2/0 A & A 0.414 133,100 2/0 - 0.438 133,100 2/0 B 0.419 167,800 3/0 A & A 0.464 167,800 3/0 - 0.492 167,800 3/0 B 0.470 211,600 4/0 A & A 0.522 211,600 4/0 - 0.522 211,600 4/0 B 0.528 Add the circular mils of the wires you wish to splice; that sum would be used to determine the correct splice using the Min/Max columns on the table above. The tables to the right are for reference only. SEAMLESS TUBING COLOR-CODE AND DIE INDEX BEVELED ENTRY ELECTRO-TIN PLATED Type YSCM HYLINK™ seamless parallel splice connectors permit stranded wires to be laid parallel inside the connector and spliced together with BURNDY® compression tools. Each YSCM connector accommodates a wide range of conductors and is color-coded to ensure proper tool and die match. YSCM connectors are cULus Listed Wire Connectors per UL 486A/B. Additionally, they are cULus Listed for Grounding and Bonding per UL 467 and rated for direct burial in Earth and Concrete. (TYPICAL INSTALLATION)